Heater without Airconditioning Have you noticed that warm air exits from the internal vent even when
all the controls are set to cold? The reason is that the heater core always has hot water passing through it with the heat control achieved by varying the amount of air directed through the heater matrix.
This approach may have been OK in the cold UK but in other hotter parts of the world the occupants will soon be roasted. The cure is simply control the water flow with a tap in the heater water hose
leading from the head.
Inspection will show that this area is very confined with the distributor, scuttle and duct all constraining the fitting of a tap.
A number of choices are open - a simple gate tap screwed into the head or inserted in the hose either cable or vacuum operated. Both GM and Ford have a number of types but note the diameter of the hose
fitting. The main problem is space. The simplest solution is a tap available from your plumbing suppliers for less than $10. This has a male thread on one side and femal on the other.
The male will screw directly into the head once the original outlet is removed. This outlet can then be screwed into the female side of the tap - no other parts are required. When removing the outlet from
the head a socket spanner will probably be too short so use a correctly fitting ring spanner to avoid rounding the flats and bruising your knuckles.
During installation of the tap it may be necessary to remove the handle and shaft to ensure that it does not foul the distributor while screwing it into the head. With the tap installed at a
convenient angle, cut off 30mm from the U shaped hose at the head end. Before refitting interchange the two hose connections to the heater at the firewall to provide more space for the U bend.
The purist may wish to fit an extension shaft to the tap handle to avoid reaching down under the air duct. Replace the air duct ensuring that both side seals effectively block out the engine heat.
Run the motor up to normal temperature with the tap open and check for leaks. Because the heater matrix is now operating with a reversed flow, the water should be drained completely and the system refilled
with clean water and rust preventative.
Finally why did Triumph make a heating system without a hot water tap? Well actually those TR7s with fully integrated air-conditioning
do have a tap - mounted inside on the heater body but in the outlet line with a thermostat responding to the heater core temperature. In this situation the heater matrix will still tend to get hot after an
hour or so even with the tap off - a dubious triumph indeed!
Philip Johnstone (Aus). |