| After all the mods (high flow waterpump, 4 row radiator, electric pusher fan, 
front scoop, etc.) I think I finally got my overheating problem solved.  I had 
the briliant idea to check the temp sending unit.  I had ordered a 300 (150 C) 
degree sending unit from e-gauges but it turns out they sent me a 250 (120 C) 
degree unit.  Fortunately, I still had my original intake manifold, so I pulled 
the sending unit off it and put it in.  Now I'm running a cool < 200 even with 
the 90+ temps we've been having.
For those intereseted, the markings on the sending unit are VDO, 8.75, 150C, 
6-24V, 801/9/1.