healeys
[Top] [All Lists]

DC electric motors

To: richchrysler@quickclic.net, glemon@neb.rr.com, healeys@autox.team.net
Subject: DC electric motors
From: SJNNOCK@aol.com
Date: Thu, 15 Sep 2005 22:53:45 EDT
    The heater motor in the Austin Healey is a DC electric motor , the field
windings are parallel to the armature , to reverse the rotation of this motor
you would have to change the flow of electricity through the field widings OR
through the armature ... when you change your battery to negative ground you
are reversing the flow of electricity through the field windings AND the
armature , the motor will still run in the same direction as before ...

   The radiator fan motors on a MGB have permanent magnets , so if you
connect the motor   backwards you have reversed the flow of electricity ONLY
through
the armature ... ie . motor runs backwards , engine   will overheat ...
Norman Nock

Gary A, can you use this




British Car Specialists   2060 N Wilson Way , Stockton , CA 95205
    (209)948-8767                   FAX # (209) 948 - 1030

                    www.britishcarspecialists.com

                    britishcardoc@sbcglobal.net





AUSTIN HEALEY TECH TALK by Norman Nock
2005 updated issue has 243 pages
l have been writing technical articles for the Healey clubs for over 20
years. After numerous requests l have gathered them together along with some
never
before published articles and had them spiral bound in book form.
Send $35.00 plus $ 4.00 shipping ( U.S.Funds )
British Car Specialists .. 2060 N Wilson Way ... Stockton .CA 95205




<Prev in Thread] Current Thread [Next in Thread>