healeys
[Top] [All Lists]

[Healeys] Fuel gauge reading full at all times

Subject: [Healeys] Fuel gauge reading full at all times
From: rchaskell at earthlink.net (Bob Haskell)
Date: Sun, 24 Sep 2017 08:56:43 -0400
References: <007101d334ec$0d4ca790$27e5f6b0$@roadrunner.com> <20170924043319.4599892.99487.9574@gmail.com> <021601d334ee$f9e399e0$edaacda0$@roadrunner.com>
Bruce,

Sounds like you need to check the harness from the sender to the gauge. 
Resistance should be close to zero.

Cheers,

Bob Haskell
AHCA 3000 MkI registrar
http://www.ciahc.org/registry_3000mk1.php

On 09/24/2017 12:38 AM, Bruce Steele wrote:
> Thanks Roland.  I should have also mentioned that I have a ground wire 
> from the collar of the sending unit to the frame.  But I also did not 
> check that it was a good ground at this point.  It was previously.
> 
> Bruce Steele
> 
> Brea, CA
> 
> 1960 BN7
> 
> *From:* Roland Wilhelmy [mailto:sentenac.rw at gmail.com]
> *Sent:* Saturday, September 23, 2017 9:33 PM
> *To:* Bruce Steele <healeybruce at roadrunner.com>
> *Subject:* Re: [Healeys] Fuel gauge reading full at all times
> 
> Bad ground connection to sender would look like high ohm connection and 
> give you a 'full' reading. That's my guess anyhow
> 
> -Roland0
> 
> Sent from my BlackBerry 10 smartphone.
> 
> *From: *Bruce Steele
> 
> *Sent: *Saturday, September 23, 2017 9:27 PM
> 
> *To: *'Healey List'
> 
> *Subject: *[Healeys] Fuel gauge reading full at all times
> 
> After the harness meltdown, which impacted the battery lead to the fuel 
> gauge, the gauge has read full and there is currently about ? in the 
> tank.  The gauge has been checked twice and pronounced OK.  Today I 
> bypassed the tank-sender wire with a jumper, same result?reading full.  
> I removed the sender and bench tested the resistance and got 2 ohms with 
> the float fully down and around 70 ohms with the float lifted to 
> approximately where it would be in a full tank.  From what I can find 
> online this is in range.  So I?m stumped as to why the gauge is reading 
> full.  Thoughts?
> 
> Bruce Steele
> 
> Brea, CA
> 
> 1960 BN7
> 
> 
> 
> 
> 
> _______________________________________________
> Support Team.Net http://www.team.net/donate.html
> Suggested annual donation  $12.75
> Archive: http://www.team.net/archive
> Forums: http://www.team.net/forums
> 
> Healeys at autox.team.net
> http://autox.team.net/mailman/listinfo/healeys
> 
> Unsubscribe/Manage: http://autox.team.net/mailman/options/healeys/rchaskell 
> at earthlink.net
> 

<Prev in Thread] Current Thread [Next in Thread>