Listers,
Eleven  TR4A owners responded with spec readings off their stock Lucas 
distributors VACUUM ADVANCE units. Thankyou all.
Eight  owners reported;
2-6-3
Legend:
A = required vacuum to start advancing 
B = vacuum at which maximum advance occurs 
C = maximum advance in degrees
Three  owners reported:  
4-14-8
5-17-10  and  
5-13-10
  
The minority units above; need higher vacuum to get started, can handle a 
higher vacuum range, and can provide up to 7 degrees more advancement.
Which is stock? Probably 2-6-3. Which is better? I don't know enough about it 
- the capability of 7 degrees more advancement might make your motor more 
responsive OR cause tuning difficulties.
About halfway through TR4 production (CT17954) the vacuum unit was updated 
(probably to 2-6-3) and I think it ran unchanged through the duration of 
TR4-A production. If anyone has more info - please speak up.
Regards,
Carl Sereda
'63 TR4 since '74 - CT22326L
 |