Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Healeys\]\s+100\-4\s+Voltage\s+Regulator\s+\(BN1\s+\&\s+BN2\)\s*$/: 2 ]

Total 2 documents matching your query.

1. [Healeys] 100-4 Voltage Regulator (BN1 & BN2) (score: 1)
Author: "Doug Newton" <dougnewton@sbcglobal.net>
Date: Sat, 8 Mar 2008 16:02:45 -0600
Good afternoon List- Is there a way to check a 100-4 Voltage Regulator to see if it is working properly if the unit is removed from the car? Thanks- Doug _____________________________________________
/html/healeys/2008-03/msg00165.html (6,540 bytes)

2. Re: [Healeys] 100-4 Voltage Regulator (BN1 & BN2) (score: 1)
Author: Norman Nock <sjnnock@sbcglobal.net>
Date: Sat, 8 Mar 2008 21:01:13 -0800 (PST)
Doug ... You would have to spin a generator at 1500 R.P.M to check open circuit voltage , 15.8v to 16.4 v ... you could check the air gaps as shown in the factory service manual and on page 210 in my