1. [Healeys] another generator question (score: 1)
Author: S and T Miller <stmiller96@hotmail.com>
Date: Tue, 14 Dec 2010 21:00:03 -0500
My 1959 100-6 BN4 generator died (22489B). I acquired a BN1 generator(22456). The pulley is different between the two and also the rear oiling system. The mounting spacing is the same. If I swap the
/html/healeys/2010-12/msg00369.html (7,206 bytes)

2. Re: [Healeys] another generator question (score: 1)
Author: Alan Seigrist <healey.nut@gmail.com>
Date: Wed, 15 Dec 2010 18:16:27 +0800
They are basically the same. Actually, the earlier ones are a bit better built, so I see no problems with this. -- Sent from my mobile device _______________________________________________ Healeys@a
/html/healeys/2010-12/msg00375.html (8,518 bytes)

3. Re: [Healeys] another generator question (score: 1)
Author: S and T Miller <stmiller96@hotmail.com>
Date: Wed, 15 Dec 2010 18:07:33 -0500
Thanks for all the responces so far. I like to share with the group when I learn something new. I did learn that the BN1 puts out 22 max. cont. output (amps) and the BN4 puts out 25 max. cont. output
/html/healeys/2010-12/msg00385.html (10,014 bytes)

4. Re: [Healeys] another generator question (score: 1)
Author: Alan Seigrist <healey.nut@gmail.com>
Date: Thu, 16 Dec 2010 07:31:28 +0800
Actually, the 22 amp might actually be better, less chance of frying your VR if you drain the battery. As long as you don't have a high powered boom box or 4 fog lights on the front you should be fin
/html/healeys/2010-12/msg00386.html (10,883 bytes)

5. Re: [Healeys] another generator question (score: 1)
Author: David Nock <healeydoc@sbcglobal.net>
Date: Wed, 15 Dec 2010 16:13:37 -0800
The generator output is controlled by the Voltage Regulator not the David Nock British Car Specialists Stockton Ca 95205 209-948-8767 www.britishcarspecialists.com . . _______________________________
/html/healeys/2010-12/msg00387.html (11,324 bytes)

6. Re: [Healeys] another generator question (score: 1)
Author: dwflagg@juno.com
Date: Wed, 15 Dec 2010 20:00:22 -0500
The regulator, Lucas 37183, is used from the BN1 through the BJ7. The BJ8 used Lucas 37331. This would mean, I believe, that the output should be consistently close to the same for all cars up the to
/html/healeys/2010-12/msg00388.html (8,180 bytes)

7. Re: [Healeys] another generator question (score: 1)
Author: John Harper <ah@jharper.demon.co.uk>
Date: Thu, 16 Dec 2010 12:11:29 +0000
May I chip in here. What matters with a generator is that it must not overheat as it will burn out if taken much above its maximum output rating. This is why regulation voltage is set at a given temp
/html/healeys/2010-12/msg00394.html (9,310 bytes)