Mike,

Just replaced my blower motor.  Easy as pie if you end up needing to switch 
but you're right to check out the motor first.  Here's an easy check, run a 
hot and ground wires to the two wires coming out of the fan (there's about 3 
inches of wire off the fan with bullet connections).  

If it runs then check the interior switch and the fuses.  

If it hums but does not really run then take it out and check for an 
obstruction - no obstruction = bum motor.

If it does not run I'd take it out and see if you can get a used one (new are 
about $70).

Oh, BTW, if you have the blower motor out get the shop vac and vacuum out the 
box.

Personally, I've never had a blower motor fail but I have had the fan 
self-destruct on a few.

Good luck,

Dr. Doug 



-----Original Message-----
From:   owner-mgs@autox.team.net  On Behalf Of miker15@juno.com
Sent:   Sunday, October 19, 1997 11:06 PM
To:     mgs@autox.team.net
Subject:        heater problem

With the onset of chillier days i have decided that the 69 needs to have
a 
WORKING heater as opposed to what it presently has..............
At present the fan does not work though warm air will drift into the car
under its own pressure - so i think the core is clear

I guess i have either an electrical malfunction or a dud fan motor but 
before i delve into it i thought id ask if anyone has done this and has
an idea of the 
order in which to check things - i looked over the connections today and
they seem
fine

mike robson
69 roadster
70 BGT
72 roadster