mgs
[Top] [All Lists]

Re: [Mgs] MGA sputtering engine and bad replacement parts

To: simon.d.matthews@gmail.com
Subject: Re: [Mgs] MGA sputtering engine and bad replacement parts
From: Bob Howard <mgbob@juno.com>
Date: Mon, 30 Nov 2009 09:59:13 -0500
   Somehow we got into the practice of replacing points & condensers at
the same time. As far back as I remember, the job was almost one word -
points&condenser.  
  TD condensers were soldered to a bracket on the plate. In the workshop
manual it is written that condensers should be changed only when needed,
implying that several sets of points would be worn out before condenser
was bad.  Changing the condenser required un-soldering the condenser from
the bracket and soldering in a new one.
Bob
 


On Thu, 26 Nov 2009 07:20:28 -0800 Simon Matthews
<simon.d.matthews@gmail.com> writes:
> Robert,
> 
> I have suggested on s3veral occasions on this mailing list that
> condensers should not be replaced unless they have failed. There is
> plenty of anecdotal evidence to suggest that condensers have a high
> early failure rate, but  those that survive early failure will last
> for a long time (many decades).
> 
> Hence, by routinely replacing condensers, you are much more likely 
> to
> have a condenser fail, because you risk the early failure of your
> newly replaced condenser.
> 
> Simon
____________________________________________________________
Online Doctorate Degrees
Find leading online Phd programs. Study anywhere anytime.
http://thirdpartyoffers.juno.com/TGL2141/c?cp=Eh3WhKFP3MmKKXuOsaX2NAAAJ1CFcZuYg3ZrSi-zVv-uUL-FAAQAAAAFAAAAABdblT4AAAMlAAAAAAAAAAAAAAAAAAaUcwAAAAA=

_______________________________________________

Support Team.Net  http://www.team.net/donate.html

Mgs@autox.team.net
http://autox.team.net/mailman/listinfo/mgs

http://www.team.net/archive

<Prev in Thread] Current Thread [Next in Thread>