tigers
[Top] [All Lists]

Re: [Tigers] Tiger Mk II wiring

To: <stubrennan@comcast.net>
Subject: Re: [Tigers] Tiger Mk II wiring
From: " Ron Fraser" <rfraser@bluefrog.com>
Date: Fri, 27 Apr 2012 14:43:18 -0400
Cc: tigers@autox.team.net
Delivered-to: tigers-archive@autox.team.net
Delivered-to: tigers@autox.team.net
List-archive: <http://autox.team.net/pipermail/tigers>
List-help: <mailto:tigers-request@autox.team.net?subject=help>
List-id: Sunbeam Tigers <tigers.autox.team.net>
List-post: <mailto:tigers@autox.team.net>
List-subscribe: <http://autox.team.net/mailman/listinfo/tigers>, <mailto:tigers-request@autox.team.net?subject=subscribe>
List-unsubscribe: <http://autox.team.net/mailman/options/tigers>, <mailto:tigers-request@autox.team.net?subject=unsubscribe>
Thread-index: Ac0kpA8WcKtqBnkiReiptQsknoIXBwAAG9rw engine=2.50.10432:5.6.7580,1.0.260,0.0.0000 definitions=2012-04-27_03:2012-04-27,2012-04-27,1970-01-01 signatures=0 spamscore=0 ipscore=0 suspectscore=1 phishscore=0 bulkscore=0 adultscore=0 classifier=spam adjust=0 reason=mlx scancount=1 engine=6.0.2-1203120001 definitions=main-1204270219
Stu
        This ammeter has 35 on the face and it has 2 heavy brown wires
attached.

The original generator was rated at 25A so a 30A gauge seems right.

When I converted my Tiger to an alternator system I used the same 30A
ammeter with a 55A alternator; no problem so far but then I try to keep my
battery charged all the time.

Ron Fraser

-----Original Message-----
From: stubrennan@comcast.net [mailto:stubrennan@comcast.net]
Sent: Friday, April 27, 2012 2:32 PM
To: rfraser@bluefrog.com
Cc: rande@thecia.net; tigers@autox.team.net
Subject: Re: [Tigers] Tiger Mk II wiring


>From the way my ammeter was wired,I suspect that wiring was not part of the
kit for Ammeters for Generator cars.  My gauge had never moved off zero,
maybe a twitch once in a while, so one day I traced it out.  The installer
had run some really thin, maybe #28 or so, plastic insulated wires to a
couple points that had little to do with the charging current.   Had 30A run
through these wires, there would have been a flash, maybe a fire...  I
properly wired it, and now it indicates fine.

My generator car has a +/-30A Ammeter, because that's all the generator
could produce.  Didn't the alternators on Mk 2 cars have a much higher
output than 30A, so they would need a differernt Ammeter?

Stu


-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2012.0.1913 / Virus Database: 2411/4962 - Release Date: 04/27/12
_______________________________________________

tigers@autox.team.net

Donate: http://www.team.net/donate.html
Archive: http://www.team.net/archive
Forums: http://www.team.net/forums
Unsubscribe: 
http://autox.team.net/mailman/options/tigers/tigers-archive@autox.team.net



<Prev in Thread] Current Thread [Next in Thread>