Hi All

I was getting my Tiger ready for the season and I noticed that I was not =
getting a charge at idle. The more the car warmed up, the more rpms it =
needed to keep the ignition lite off. Over the years I have experienced =
problems keeping a voltage regulator for any great length of time. They =
just seem to give up after not so long. This time I did pretty =
well=E2=80=A6it lasted over a year. I checked the battery and generator =
just to be sure=E2=80=A6the battery had a full charge and the generator =
was generating.

So I switched out the v/reg for one I purchased from SS as a backup last =
year. I have done this installation a couple of times so I was =
confident, even with my minimal skills.

I got the new v/reg in. Reconnected the battery but When I went to =
polarize it (touch F wire and B wire momentarily per Shop =
Manual)=E2=80=A6nothing. I checked my connections (Brown to Batt =
terminal=E2=80=A6Brn/Grn to Fld terminal=E2=80=A6Brn/Yel to Arm =
terminal) all were correct. I double checked battery=E2=80=A6full =
charge.

Thinking the v/reg might be bad, I reinstalled the old one=E2=80=A6same =
results=E2=80=A6nothing.

I installed new one again=E2=80=A6same results.

The only other action I took was to disconnect the terminals on the =
generator and cleaned them up. I checked to make sure I reconnected them =
correctly.

I took a chance and turned on the ignition=E2=80=A6dead.

After taking a break I went back out and did some more inspection and =
testing. Not sure if it made a difference but I found the battery wire =
(brown) spade connector at the fuse box loose. I crimped it down and got =
a much tighter fit. The v/reg still would not polarize so I then took =
some readings with my multimeter. Here are the readings=E2=80=A6


Battery=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=
=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=
=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6.12.9v

Batt Term @ =
V/reg=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=
=A6=E2=80=A6=E2=80=A6..=E2=80=A6=E2=80=A6..12.9v

Battery term @ =
solenoid=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=
=80=A6..=E2=80=A6..12.9V

Battery Term @ Gen (end of case)=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6..0



I thought I should get a similar 12 something reading at the Batt =
terminal on the generator. Any advice on where to make additional tests =
or anything else is appreciated.=20



I am pretty much a neophyte at this so please type slowly.



Thanks



Jim Lindner

------=_NextPart_000_0019_01D073CE.2981BD10
        charset="UTF-8"
Content-Transfer-Encoding: quoted-printable

<HTML><HEAD></HEAD>
<BODY dir=3Dltr>
<DIV dir=3Dltr>
<DIV style=3D"FONT-SIZE: 12pt; FONT-FAMILY: 'Calibri'; COLOR: #000000">
<DIV><FONT face=3DVerdana><FONT style=3D"FONT-SIZE: 10pt">Hi =
All<BR><BR>I was=20
getting my Tiger ready for the season and I noticed that I was not =
getting a=20
charge at idle. The more the car warmed up, the more rpms it needed to =
keep the=20
ignition lite off. Over the years I have experienced problems keeping a =
voltage=20
regulator for any great length of time. They just seem to give up after =
not so=20
long. This time I did pretty well=E2=80=A6it lasted over a year. I =
checked the battery=20
and generator just to be sure=E2=80=A6the battery had a full charge and =
the generator=20
was generating.<BR><BR>So I switched out the v/reg for one I purchased =
from SS=20
as a backup last year. I have done this installation a couple of times =
so I was=20
confident, even with my minimal skills.<BR><BR>I got the new v/reg in.=20
Reconnected the battery but When I went to polarize it (touch F wire and =
B wire=20
momentarily per Shop Manual)=E2=80=A6nothing. I checked my connections =
(Brown to Batt=20
terminal=E2=80=A6Brn/Grn to Fld terminal=E2=80=A6Brn/Yel to Arm =
terminal) all were correct. I=20
double checked battery=E2=80=A6full charge.<BR><BR>Thinking the v/reg =
might be bad, I=20
reinstalled the old one=E2=80=A6same results=E2=80=A6nothing.<BR><BR>I =
installed new one=20
again=E2=80=A6same results.<BR><BR>The only other action I took was to =
disconnect the=20
terminals on the generator and cleaned them up. I checked to make sure I =

reconnected them correctly.<BR><BR>I took a chance and turned on the=20
ignition=E2=80=A6dead.</FONT></FONT><BR></DIV>
<DIV><FONT style=3D"FONT-SIZE: 11pt">After taking a break I went back =
out and did=20
some more inspection and testing. Not sure if it made a difference but I =
found=20
the battery wire (brown) spade connector at the fuse box loose. I =
crimped it=20
down and got a much tighter fit. The v/reg still would not polarize so I =
then=20
took some readings with my multimeter. Here are the =
readings=E2=80=A6</FONT></DIV>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: 11pt"></FONT>&nbsp;</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: =
11pt">Battery=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=
=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=
=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6.12.9v</FONT></P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: 11pt">Batt Term @ =
V/reg=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=
=A6=E2=80=A6=E2=80=A6..=E2=80=A6=E2=80=A6..12.9v</FONT></P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: 11pt">Battery term @ =
solenoid=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6=E2=
=80=A6..=E2=80=A6..12.9V</FONT></P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: 11pt">Battery Term @ Gen (end of =
case)=E2=80=A6=E2=80=A6=E2=80=A6=E2=80=A6..0</FONT></P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT=20
style=3D"FONT-SIZE: 11pt"></FONT>&nbsp;</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt"><FONT =
style=3D"FONT-SIZE: 11pt">I=20
thought I should get a similar 12 something reading at the Batt terminal =
on the=20
generator. Any advice on where to make additional tests or anything else =
is=20
appreciated. </FONT></P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">&nbsp;</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">I am pretty much a =
neophyte at=20
this so please type slowly.</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">&nbsp;</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">Thanks</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">&nbsp;</P>
<P class=3DMsoNormal style=3D"MARGIN: 0in 0in 0pt">Jim=20
Lindner</P></DIV></DIV></BODY></HTML>

------=_NextPart_000_0019_01D073CE.2981BD10--



--===============8428550133803228954==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline