That voltage both side of the coil shows the points or 45DE4 trigger are not 
closed - if you had either of those.  Again if you had either of those you 
could turn the engine manually and at some point you should see the 
distributor side of the coil drop to zero volts which would be an earth from 
the points or trigger, and stay there until the engine had been turned past 
the point at which the HT is required.  But with the 45DM4 you imply you 
have this sends a very short pulse at the timing point no matter how slow 
the engine is turning.  This is why I explained you need to be more 
imaginative when doing voltage tests on the low voltage side of the coil.

You also need to clarify what you mean by getting 'nothing' at the coil when 
cranking.  Do you mean the voltage dropped to zero all the time on both 
sides while cranking?  Or nothing changed i.e. you still have the same 
voltage both sides while cranking?

PaulH.

----- Original Message ----- 
> After the responses I received, I checked the voltage on both sides of my
> coil. I am getting 11.47 volts on both sides. 