Re: Heater core

From: Rex Funk (rexfunk(at)wizzards.net)
Date: Wed Sep 23 1998 - 23:08:03 CDT


Robert J.Jaarsma wrote:

>I had the same problem once, worse the side gave up and cracked. It is
>usually caused by running with a higher pressure radiator(coolant cap).
>I had mine reinforced on the outside on both sides by a radiator shop.
>A "X" from corner to corner on either side will do the trick. Doesn't
>cost much and no more worries.

The heater core ends are the weakest part of the cooling system, and are
prone to blow with a higher pressure cap. In a tech session at SUNI I,
Tiger Tom recommended converting to a 14 lb. radiator cap, and said the only
thing that wouldn't take the pressure was (you guessed it) the heater core
ends. He recommended soldering a plate on them similar to that discribed
above. The advantage of running a 14 lb. cap is, of course, being able to
hold a higher temp (about 10 deg. F.?) without boil over. Whether or not
the 14 lb. cap is used, it's smart to reinforce the heater core ends.

Rex Funk



This archive was generated by hypermail 2b30 : Tue Sep 05 2000 - 10:16:28 CDT