| To: | Trevor Boicey <tboicey@brit.ca> |
|---|---|
| Subject: | Re: Voltage regulator logic |
| From: | Bullwinkle <yd3@nvc.net> |
| Date: | Tue, 11 Sep 2001 19:28:51 -0600 |
My guess is the field coils aren't energizing if this is a generator. The reason you're getting some voltage is due to the residual magnetism in the field coils laminations. Field coils not energizing could be: 1) burned out field coils 2) Bad connections or wires from the generator's field terminal to the regulator 3) Bad regulator Blake /// /// mgs@autox.team.net mailing list /// (If they are dupes, this trailer may also catch them.) |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | On the NY & Pentagon disaster - Thank you for caring, Jerry Erbesfield |
|---|---|
| Next by Date: | I survived the WTC disaster, Rick Brown |
| Previous by Thread: | Re: Voltage regulator logic, E.Claure |
| Next by Thread: | Re: Voltage regulator logic, paul.hunt1 |
| Indexes: | [Date] [Thread] [Top] [All Lists] |