Fraser,Ron wrote:

>  The distance I used for the water pump hub as described in the service
>  manual are as follows;
> 
>         260     4.875"     alum water pump
> 
>         289     5.1"    cast iron water pump
> 
>         These numbers came from the TE/AE  Sunbeam Surviver Manual.

> Ron Fraser


Funny, my Rootes Sunbeam "260 - 289" Workshop Manual specifies that the
"Front face of pulley hub to pump housing face is 5.15 in. (13 cm) for
the 260 (aluminum) and 5.43 in (13.8 cm) for the 289 (iron with
back-side steel plate). I wonder why TE/AE quoted Manual would differ? I
do have the referenced TE/AE manual, and the quote is correct. There is
no mention, however, of a discrepancy in the CAT Shop Notes, or
Supplement.

Any knowledge out there?

-- 