At 11:55 PM +1000 30/3/99, Cameron Greig wrote:

>My TR6 fuel gauge reads 1/2 to 3/4 when full and somewhere around the
>floor when empty.The other day when the gauge read zero I filled it
>up,only took 1/2 a tank.Before I take  the sender out to clean,any other
>ideas.

A 100 Ohm resistor across the tank sender leads should produce a reading of
one third of a tank.  This should tell you whether the guage or the sender
is at fault.  Split and sinking floats on the sender are fairly common and
it is difficult/impossible to find replacement floats, so you have to buy a
new sender (at great expense).

Trevor Jordan
74 TR6 CF29281U