Seriously, the field and armature circuits are connected (by the regulating 
contacts in the control box) and since the generator is not generating any 
voltage they battery will feed current into the generator which is only limited 
by 
the DC resistance of the field and armature windings.  The harness wiring 
cannot carry this much current for very long (which may be a good thing because 
if they could the current would burn up the generator).

So if you do this with the engine stopped pull the contacts open as quickly 
as possible.